Objectives: Identify and prospectively investigate simulated ultrasound-guided targeted liver biopsy performance metrics as differentiators between levels of expertise in interventional radiology. Methods: Task analysis produced detailed procedural step documentation allowing identification of critical procedure steps and performance metrics for use in a virtual reality ultrasound-guided targeted liver biopsy procedure. Consultant (n 5 14, male 5 11, female 5 3) and trainee (n 5 26, male 5 19, female 5 7) scores on the performance metrics were compared. Ethical approval was granted by the Liverpool Research Ethics Committee (UK). Independent t-tests and analysis of variance (ANOVA) investigated differences between groups. Results: Independent t-tests revealed significant differences between trainees and consultants on 3 performance metrics: targeting, p 5 0.018, t 5 22.487 (22.040 to 20.207); probe usage time, p 5 0.040, t 5 2.132 (11.064 to 427.983); mean needle length in beam, p 5 0.029, t 5 22.272 (20.028 to 20.002). ANOVA reported significant differences across years of experience (0-1, 1-2, 3+ years) on seven performance metrics: no-go area touched, p 5 0.012; targeting, p 5 0.025; length of session, p 5 0.024; probe usage time, p 5 0.025; total needle distance moved, p 5 0.038; number of skin contacts, p , 0.001; total time in no-go area, p 5 0.008. More experienced participants consistently received better performance scores on all 19 performance metrics. Conclusion: It is possible to measure and monitor performance using simulation, with performance metrics providing feedback on skill level and differentiating levels of expertise. However, a transfer of training study is required.
Fichier principal
Vignette du fichier
BJR130710.pdf (353.78 Ko) Télécharger le fichier
Vignette du fichier
stat.png (15.78 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)
Format Figure, Image
Loading...

Dates et versions

inria-00560487 , version 1 (25-09-2013)

Identifiants

Citer

Sheena Johnson, Carianne Hunt, Helen Woolnough, Martin Crawshaw, Caroline Kilkenny, et al.. Virtual Reality, Ultrasound-guided Liver Biopsy Simulator: Development and Performance Discrimination. British Journal of Radiology, 2011, ⟨10.1259/bjr/47436030⟩. ⟨inria-00560487⟩
322 Consultations
231 Téléchargements

Altmetric

Partager

More