SAMPLE SIZE DETERMINATION USING ROC ANALYSIS - Inria - Institut national de recherche en sciences et technologies du numérique Access content directly
Conference Papers Year : 2007

SAMPLE SIZE DETERMINATION USING ROC ANALYSIS

Abstract

The paper presents a new method of sample size determination (SSD) based on performance evaluation of systems under study. The method builds upon previous work on Bayesian approach to nonparametric receiver operating characteristics (ROC) analysis with estimation of probability density functions and confidence intervals for parameters of ROC curve. Technical details of the method together with an illustration of its application to a real clinical example is given. The advantages of the method include ability to handle and comparemodels built using multidimentional, multimodal data, with no need for prior estimation of the effect size and variability. The disadvantages of the approach include high computational requirements, especially when the method of SSD deploys AUC as a measure of systems performance.
Fichier principal
Vignette du fichier
BHC-SAMPLE-SIZE-ROC-CIMED-2007.pdf (284.44 Ko) Télécharger le fichier
Origin : Files produced by the author(s)

Dates and versions

inria-00442370 , version 1 (21-12-2009)

Identifiers

  • HAL Id : inria-00442370 , version 1

Cite

Viktoriya Stalbovskaya, Brahim Hamadicharef, Emmanuel C. Ifeachor. SAMPLE SIZE DETERMINATION USING ROC ANALYSIS. 3rd International Conference on Computational Intelligence in Medicine and Healthcare (CIMED2007), Jul 2007, Plymouth, United Kingdom. ⟨inria-00442370⟩
203 View
3504 Download

Share

Gmail Facebook X LinkedIn More