Diagnosis of Insulated Building Walls Using Passive Infrared Thermography and Numerical Simulations
Résumé
This work presents the thermal monitoring of a multi-layered wall of a restored building (PANISSE platform). Surface temperatures measured by infrared thermography are corrected by taking account of the influence parameters. Then they are compared with thermocouple measurements and numerical simulations.