Résumé

We propose a novel solution for volumetric ultrasound imaging using single-side access 3-D synthetic-aperture scanning of a clinical linear array. This solution is based on an advanced scanning geometry and a software-based ultrasound platform. The rotate-translate scanning scheme increases the elevation angular aperture by pivoting the array [-45° to 45°] around its array axis (axis along the row of its elements) and then, scans the imaged object for each pivoted angle by translating the array perpendicularly to the rotation axis. A theoretical basis is presented so that the angular and translational scan sampling periods can be best adjusted for any linear transducer array. We experimentally implemented scanning with a 5-MHz array. In vitro characterization was performed with phantoms designed to test resolution and contrast. Spatial resolution assessed based on the full-width half-maximum of images from isolated microspheres was increased by a factor 3 along the translational direction from a simple translation scan of the array. Moreover, the resolution is uniform over a cross-sectional area of 4.5 cm 2. Angular sampling periods were optimized and tapered to decrease the scan duration while maintaining image contrast (contrast at the center of a 5 mm cyst on the order of-26 dB for 4° angular period and a scan duration of 10 s for a 9cm 3 volume). We demonstrate that superior 3-D US imaging can be obtained with a clinical array using our scanning strategy. This technique offers a promising and flexible alternative to development of costly matrix arrays toward the development of sensitive volumetric ultrasonography.
Fichier principal
Vignette du fichier
Final_hal210125.pdf (2.2 Mo) Télécharger le fichier
FigureS1.png (795.55 Ko) Télécharger le fichier
VideoS1.mp4 (4.53 Mo) Télécharger le fichier
VideoS2.mp4 (2.12 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03011745 , version 1 (18-11-2020)
hal-03011745 , version 2 (25-01-2021)

Identifiants

Citer

Théotim Lucas, Isabelle Quidu, S. Lori Bridal, Jerome Gateau. High contrast and resolution 3-D ultrasonography with a clinical linear transducer array scanned in a rotate-translate geometry. Applied Sciences, 2021, 11 (2), pp.493. ⟨10.3390/app11020493⟩. ⟨hal-03011745v2⟩
196 Consultations
120 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More